1000 SCFM THERMAL OXIDIZER TRAILER MOUNTED
Gas Fired FM-G Thermal Oxidizer System Design Data
| Flow Rate: |
100 |
300 |
500 |
1000 |
1500 |
2000 |
3000 |
4000 |
SCFM |
| Inlet Temp: |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
F |
| Outlet Temp: |
1400 |
1400 |
1400 |
1400 |
1400 |
1400 |
1400 |
1400 |
F |
| |
|
|
|
|
|
|
|
|
|
| Max Burner Input: |
1.0 |
1.0 |
1.0 |
2.0 |
3.0 |
4.0 |
6.0 |
8.0 |
MM Btu |
| Gas Press: |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
PSI |
Refractory Lining:
|
6 |
6 |
6 |
6 |
6 |
6 |
6 |
6 |
In |
| Chamber Size: |
6 |
20 |
30 |
60 |
90 |
120 |
180 |
240 |
Cu.ft. |
| Residence Time: |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
Second |
| Destruction Eff.: |
99 |
99 |
99 |
99 |
99 |
99 |
99 |
99 |
% |
| |
|
|
|
|
|
|
|
|
|
| SHELL DIM. (OD) |
|
|
|
|
|
|
|
|
|
| (Add 18" for panel) |
36 |
36 |
36 |
48 |
48 |
48 |
60 |
60 |
Width |
| |
42 |
42 |
42 |
54 |
54 |
66 |
72 |
72 |
Height |
| (Add 24" for burner) |
48 |
60 |
120 |
96 |
120 |
120 |
120 |
144 |
Length |
| |
|
|
|
|
|
|
|
|
|
| WEIGHT: |
600 |
1000 |
1500 |
2000 |
2800 |
3400 |
5000 |
8000 |
LBS. |
|